UV Exploded View

Installation
If you have a severe algae problem you should effect a partial water change before starting the installation. Algae Masters can be added to any existing filtration system. For best results the unit should be fitted in line, after the pump, with water being forced through it. Use the largest size of pipe possible. If hosetails are to be used, it is very important that they are trimmed to the largest possible size that will fit inside the flexible pipe (before glueing in place). This will ensure that the maximum flow rate can be obtained for the size of pipe.

Algae Masters have been designed to run for twenty four hours a day, twelve months of the year. They should be installed in a well ventilated position but protected from frost and at no time allowed to freeze.

If you are unable to position the unit in a location where it will not freeze, you should make allowances during the installation to ensure you can easily remove it for storage during the colder times of the year.

Maintenance
Although maintenance is minimal all UV lamps need replacing at six monthly intervals. The lamp may be illuminated and appear to be working but the radiation dosage diminishes with age and is ineffective after six months. Dispose of used lamps sensibly. Even exhausted lamps should NEVER be looked at directly when illuminated.

As the unit is dependant upon water passing through it, it is important to ensure that any pump strainers, pre-filters or delivery pipes are not blocked or are causing the flow to be restricted.

To change the lamp
Isolate unit from mains power, turn off pump, remove shower-proof ends and lamp holder, carefully slide out lamp, undo circular nut at each end of unit, remove “O” rings, one from each end, carefully slide out quartz sleeve. To clean use rag dampened with pond water, wipe dry with a cloth and reinstall. Use no chemical cleaners harmful to fish. To reinstate slide silica quartz sleeve back into position carefully, reposition “O” rings at either end over quartz, centralise tube with an even amount protruding at either end, replace nuts (hand tighten only), turn on pump and test for leaks, if on inspection no leaks are apparent replace lamp as above and reconnect.

WARNING
Do not look at the lamp when on (even old or exhausted lamps)
Do not submerge unit
Do not run without a constant water flow (the unit is watercooled)
Do not allow water to freeze within the unit
Do not open while switched on
Do not use with broken or chipped quartz sleeve

Algae Masters are guaranteed for 12 months excluding lamps and breakages

 